Fully configurable 0-6 valve stack to meet all workholding needs with no duty cycle limitation due to VFD thermal protection and a large 5-Gallon reservoir designed for maximum useable oil volume.
Central or remote power supply configured with "P" (pressure out) and "T" (tank return flow) port only Valves usually mounted on the machine closer to the application, Valves Typically mounted behand or between 2 machines. Requires remote shear seal or poppet style zero leak valve. Supply your own off board valve.
Valve # |
100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
0 | 55-9675-00 | 55-9695-00 |
Can use coupled or uncoupled. Recommended to run a continuously connected or single hose supply decoupled system. Operator interface is a manual valve handle. Pump located within operators reach.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-12-1 | 55-9695-12-1 |
Recommended to run a continuously connected or single hose supply decoupled system where, the pressurized time exceeds the unpressurized time. Operator interface is by remote pendant or can be wired into a machine controller.
NOTE: Should not be used with palletized systems as the valve is energized to unclamp. The unclamped time will be excessive, causing the valve to run hot.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-23-1 | 55-9695-23-1 |
2 | 55-9675-23-2 | 55-9695-23-2 |
4 | 55-9675-23-4 | 55-9695-23-4 |
Recommended for continuously connected "live" systems. Always connected to the fixture by means of hoses and or rotary unions. Operator interface is a manual valve handle. Pump located within operators reach.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-16-1 | 55-9695-16-1 |
2 | 55-9675-16-2 | 55-9695-16-2 |
4 | 55-9675-16-4 | 55-9695-16-4 |
Recommended for continuously connected "live" systems. Always connected to the fixture- by means of hoses and or rotary unions. Center position allows no movement of clamps when the valve is de-energized. Operator interface is by remote pendant or can be wired into a machine controller.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-26-1 | 55-9695-26-1 |
2 | 55-9675-26-2 | 55-9695-26-2 |
4 | 55-9675-26-4 | 55-9695-26-4 |
Can use coupled or uncoupled. Recommended to run a continuously connected or single hose supply decoupled system. Operator interface is by a manual valve handle. Pump located within operators.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-12-1 | 55-9695-25-1 |
Single Acting Decoupled Systems Valve installed with a control pendant to power systems using the Self-closing Decoupler and Tombstone Top Plates. Commonly called a "dump pump" and uses a momentary contact pendant switch. When preset pressure is reached the control valve automatically shifts and dumps pressure back to tank. Operator interface is by remote pendant or can be wired into a machine controller.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-25-1 | 55-9695-25-1 |
Single Acting Live systems. Use with Manual Pallet Decouplers, Tombstone Top Plates and Self-Closing (single hose) Decouplers Operator interface is by remote pendant or can be wired into a machine controller.
NOTE all decoupled valves are de-energized when not in use to avoid heat build up between cycles.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-24-1 | 55-9695-24-1 |
2 | 55-9675-24-2 | 55-9695-24-2 |
4 | 55-9675-24-4 | 55-9695-24-4 |
Double or Single Acting run live or decoupled. Control Auto-Shutoff Pallet Decoupler (2 hose system)> Operator interface is a manual valve handle. Best selection for fixture testing, runs most systems.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-17-1 | 55-9695-17-1 |
Reduces pressure to clamp or unclamp side of a circuit. Use with one or two handed Auto-Shutoff Decoupler. P-blocked center valve drops pressure in both lines. Allows decoupling and re-coupling of the hoses. used to operate two individual single acting systems at different pressures. Operator interface is remote pendant or wired into a machine controller.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-28-1 | 55-9695-28-1 |
Double or Single Acting. Use 1 or 2 handed Auto-Shutoff Pallet Decoupler. Uses a P-Blocked center to drop pressure in both lines to decouple and re-couple hoses. Operator interface is by remote pendant or can be wired into a machine controller.
# | 100-200 VAC 1-Phase | 380-500 VAC 3-Phase |
---|---|---|
1 | 55-9675-27-1 | 55-9695-27-1 |
2 | 55-9675-27-2 | 55-9695-27-2 |
4 | 55-9675-27-4 | 55-9695-27-4 |
NOTE: Contact factory for custom pump configurations.
NOTE: Voltages listed are input to control box for pump motor. All solenoid valves use 24 VDC control voltage supplied by the transformer internal to the pump control box. Wiring of control valves supplied with pump is not required.
NOTE: Solenoid valves configurations are supplied with one valve control pendant with a 6 ft. cable. For additional pendants order from the chart.
NOTE: See pump manual to calculate the required electrical service for your specific application.
NOTE: All 115VAC single phase pumps require a 20 AMP dedicated service electrical connection for proper operation and service life.
Pendant Model No. | Pendant Switch or Machine Control Options |
---|---|
95-5955-37 | Pendant, 6 ft., 2-Position 3-Port Normally Open (On-Off) |
95-5955-38 | Pendant, 6 ft., 2-Position 3-Port Normally Closed (Off - On ) |
95-5955-39 | Pendant, 6 ft., 2-Position 3-Port Normally Closed (Off - Momentary - On) |
95-5955-40 | Pendant, 6 ft., 3-Position 4-Port Normally Closed Center, or PBC , (On - Off - On) |
27-7422-03 | Pendant Extension Cable M12, 16.4 ft. |
27-9422-02 | Pendant Extension Cable M12, 32.8 ft. |
95-5990-15 | 2-Hand No-Tie-Down Control Module (Decoupled Systems Only) |
Pendant Model No. | CNC Machine Control |
---|---|
95-5955-23 | Pump/Machine Tool Interface Cable. 1 - 4 Valves, 36 pins 16.4 ft. |
95-5954-50 | Pendant,Valve Wiring cable, 1 Valve M12, 5 Pin, and 16.4 ft. 6 ft., 2-Position 3-Port Normally Closed (Off - On ) |
Model # | Pump flow rate (cu. in) Stage1 |
Pump flow rate (cu. in) Stage2 |
Pump Pressure Range (psi) Stage1 |
Pump Pressure Range (psi) Stage2 |
Reservoir Capacity (gal) Gross |
Reservoir Capacity (gal) Usable |
Oil Viscosity c St 4-C Min to Max |
Basic Weight (lbs) No valves |
---|---|---|---|---|---|---|---|---|
55-96X5-XX | 420 | 125 | 0-1450 | 1450-5000 | 5.0 | 3.5 | 22-46 | 180 |