High Pressure Link Clamp Lever Dimensions
0.28
All dimensions are in inches.
High Pressure Link Clamp Output Curves
NOTE: Modifications to levers that result in clamp ratios below a 1:1 ratio are not in the safe operating zone for the corresponding link clamp and could result in premature failure.
Exceeding the allowable offset values and operating pressures specified in the tables will result in excessive forces on the link clamp pins, links,and rod which could result in premature failure.
Low Pressure Link Clamp Lever Dimensions
91-6011-03
550
1.88
0.75
0.50
0.2515
0.19
0.2505
91-6015-03
1100
2.63
1.00
0.3765
0.31
0.3755
91-6021-03
2200
3.09
1.25
0.88
0.5015
0.38
0.5005
1.19
91-6011-02
3.00
91-6015-02
3.50
91-6021-02
4.00
0.13
0.25
0.26
1.69
1/4-20 UNC
0.69
0.39
2.25
3/8-16 UNC
0.94
0.44
0.45
2.69
1/2-13 UNC
N/A
Low Pressure Link Clamp Output Curves
Exceeding the allowable offset values and operating pressures specified in the tables will result in excessive forces on the link clamp pins, links and rod which could result in premature failure.