L1-4025-10-L-0 L1-4025-10-L-30 L1-4025-10-L-60 L1-4025-10-L-90 L1-4025-10-L-120 L1-4025-10-L-150 L1-4025-10-R-0 L1-4025-10-R-30 L1-4025-10-R-60 L1-4025-10-R-90 L1-4025-10-R-120 L1-4025-10-R-150 L1-4025-10-S-0 L1-4025-10-S-30 L1-4025-10-S-60 L1-4025-10-S-90 L1-4025-10-S-120 L1-4025-10-S-150
L1-4032-10-L-0 L1-4032-10-L-30 L1-4032-10-L-60 L1-4032-10-L-90 L1-4032-10-L-120 L1-4032-10-L-150 L1-4032-10-R-0 L1-4032-10-R-30 L1-4032-10-R-60 L1-4032-10-R-90 L1-4032-10-R-120 L1-4032-10-R-150 L1-4032-10-S-0 L1-4032-10-S-30 L1-4032-10-S-60 L1-4032-10-S-90 L1-4032-10-S-120 L1-4032-10-S-150
L1-4040-10-L-0 L1-4040-10-L-30 L1-4040-10-L-60 L1-4040-10-L-90 L1-4040-10-L-120 L1-4040-10-L-150 L1-4040-10-R-0 L1-4040-10-R-30 L1-4040-10-R-60 L1-4040-10-R-90 L1-4040-10-R-120 L1-4040-10-R-150 L1-4040-10-S-0 L1-4040-10-S-30 L1-4040-10-S-60 L1-4040-10-S-90 L1-4040-10-S-120 L1-4040-10-S-150
Cylinder Capacity (kN)*
Bore Size
Vertical Clamp Stroke (mm)**
Total Stroke (Swing and Vertical) (mm)
Effective Piston Area (cm2) Retract
Oil Capacity *** (cm3) Extend
Oil Capacity *** (cm3) Retract
Optional Flow Control Model No.
L1-4050-10-L-0 L1-4050-10-L-30 L1-4050-10-L-60 L1-4050-10-L-90 L1-4050-10-L-120 L1-4050-10-L-150 L1-4050-10-R-0 L1-4050-10-R-30 L1-4050-10-R-60 L1-4050-10-R-90 L1-4050-10-R-120 L1-4050-10-R-150 L1-4050-10-S-0 L1-4050-10-S-30 L1-4050-10-S-60 L1-4050-10-S-90 L1-4050-10-S-120 L1-4050-10-S-150
L1-4063-10-L-0 L1-4063-10-L-30 L1-4063-10-L-60 L1-4063-10-L-90 L1-4063-10-L-120 L1-4063-10-L-150 L1-4063-10-R-0 L1-4063-10-R-30 L1-4063-10-R-60 L1-4063-10-R-90 L1-4063-10-R-120 L1-4063-10-R-150 L1-4063-10-S-0 L1-4063-10-S-30 L1-4063-10-S-60 L1-4063-10-S-90 L1-4063-10-S-120 L1-4063-10-S-150
L1-4080-10-L-0 L1-4080-10-L-30 L1-4080-10-L-60 L1-4080-10-L-90 L1-4080-10-L-120 L1-4080-10-L-150 L1-4080-10-R-0 L1-4080-10-R-30 L1-4080-10-R-60 L1-4080-10-R-90 L1-4080-10-R-120 L1-4080-10-R-150 L1-4080-10-S-0 L1-4080-10-S-30 L1-4080-10-S-60 L1-4080-10-S-90 L1-4080-10-S-120 L1-4080-10-S-150
175.9
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation.
*Cylinder retract capacities are listed at 7 MPa (70 bar) operating pressure. Divide cylinder retract force by 2 for when using symmetrical length arm. Maximum operating pressure is 10 MPa (100 bar). The minimum operating pressure is 1 MPa (10 bar). The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 7 MPa (70 bar), and multiply the resultant number by your system operating pressure MPa (bar) to obtain the approximate retract force for your application. (Actual force will vary slightly due to internal loading, and/or friction loss.)
** To allow for piece part height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke.
*** To ensure maximum service life and trouble-free operation, restrict fluid flow per Table.
**** In-port flow control requires the use of manifold mount ports.
Double Acting
A
B
C
D
E
F
G
H