Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point. The PRV is designed for use in both single-acting and double-acting systems.
Model No. L7-0530-00 Cartridge Only
Note: For cavity tooling (multistep Reamer), order kit 62-7050-00.
Pressure Graph
The graph shows the pressure drop through a PRV and manifold mount block.
The graphs show the repeat range based on set pressure.