140 bar -350 bar (14-35 MPa)
16 cm3
70 bar -250 bar (7-25 MPa)
49-0116-01
52 cm3
49-0116-02
59 cm3
20 bar -100 bar (2-10 MPa)
62 cm3
All dimensions are in mm.
NOTE: Please check accumulator's gas pre-charge during your annual maintenance check. Consult factory if you require assistance.
Hydraulic fluid compresses the precharged inert gas across the piston during circuit pressurization. The pressurized gas provides additional fluid to the circuit to reduce pressure changes in the event of small seeps, or thermal expansion or contraction while the pallet or column fixture is in the machine. The 140 bar (14 MPa) - 350 bar (35 MPa) operating pressure model has gas precharged to 100 bar. The 70 bar (7 MPa)- 240 bar (24 MPa) operating pressure model has gas precharged to 50 bar. Perform annual maintenance in accordance with the instructions provided with each accumulator. Contact Vektek for additional copies of the annual maintenance instructions or to arrange for factory performed annual maintenance.
Strictly observe all safety precautions provided with each accumulator.
NOTE: This Manual Shutoff Valve Decoupler must be used with a suitable pump which includes a 2-position/3-port, directional control valve for operation of one single acting circuit. Contact Vektek for considerations in the use of this Manual Shutoff Decoupler to control double acting circuits