Setup Guide
45-0485-00
10
45-0485-01
Min. 3.1
6.6-13.3
Min. 3.10
1.5 - 3
* Pressure drop when one or more valves open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel.
E = Input
A = Output (Vent to atmosphere)
The Pneumatic Confirmation Valve confirms the stage of loading before or after clamping. It is adaptable to multiple devices including: swing clamps, link clamps, cylinders and supports. Avoid machine crashes by confirming specific actions before you cycle your machine. It is designed to be used in both coolant and dry environments, and is easily mounted either vertically or horizontally. Confirmation at its finest!
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm Ra