Dimensions
47-0540-01
350 bar
(35 MPa)
52-310 bar
(5.2 -31.0 MPa)
47-0540-03
< 200 bar
(20 MPa)
10- 62 bar
(1-6.2 MPa)
>200 bar
20-62 bar
(2.0 - 6.2 MPa)
* Maximum system flow rate is 5.7 l/min. for all VektorFlo® special function valves. Excess flow voids warranty.
Order a Filter Plate to protect valves from debris (Model No. 47-0842-02).
(5.2 -31.0 MPa
10 - 62 bar
>200 bar 20 MPa)
20-62 bar (2.0 - 6.2 MPa)
Low Pressure PRV added to the Product Line
Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point. The PRV is designed for use in both single-acting and double-acting systems.
Cartridge Dimensions
>200 bar (20 MPa)
Pressure Graph
The graph shows the pressure drop through a PRV and manifold mount block.
The graphs show the repeat range based on set pressure.