Double and Single Acting
41-4202-11
41-4202-12
Right
Left
2
41-4205-11
41-4205-12
4.9
41-4211-11
41-4211-12
11.6
41-4202-21
41-4202-22
41-4205-21
41-4205-22
41-4211-21
41-4211-22
Warning! Never allow swing arm to contact workpiece or fixture during arm rotation.
* Cylinder capacities are listed at 350 bar (35 MPa) maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 52 bar (5.2 MPa) for single acting, 35 bar (3.5 MPa) for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 350, and multiply the resultant number times your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)
** To allow for workpiece height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke.
*** To insure maximum service life and trouble-free operation, restrict fluid flow to the level indicated in the Clamp Time and Flow Rate Chart.
**** In-port valves require the use of manifold mount ports.
U.S. Patent Nos. 6,886,820 7,032,897
BHC™ (Black Hard Coating) on the cylinder bodies helps prevent scoring and scratching.
Bottom unclamp porting is available.
Vent port with bronze filter gives single acting swing clamps a place to "breathe" and helps keep contamination from entering breather port.
Dimensions
71
M12 x 1.75 Depth 13
M6 x 1 Depth 7
M10 x 1.5 Depth 12
Mounting
20