Dimensions
All dimensions are in inches.
Model No. 70-4400-01 Assembly Model No. 70-4400-02 Assembly
Operation: The VektorFlo® sequence valve operates as a pressure sensitive, normally closed element in a clamping system. When fluid first enters the system at low pressure, the valve is closed, blocking the flow of fluid to devices down stream. After devices in the other branches of the system have moved into position, the pressure begins to increase. The increasing pressure overcomes the spring force holding the valve closed, forcing the poppet off its seat, and allowing fluid flow through the valve. After all devices have positioned and clamped, the downstream pressure increases to equal upstream pressure. Pressure throughout the system will increase to the maximum setting on the hydraulic power supply. When unclamping, as pressure falls, force from the adjustment spring pushes the poppet back onto its seat. Fluid trapped in the downstream circuit flows back through the check seat to return to the power unit reservoir.
Cartridge Dimensions
3.0 GPM
*Maximum Inlet Pressure for sequence valve is 5000 psi, excess voids warranty.
Model No. 70-4430-01 and 70-4430-02 Cartridge Cavity
NOTE: If a sequence valve is no longer needed use 30-6011-20 plug to cap cavity for free fluid pass through.
NOTE: For Cavity tooling (multistep reamer and M20 x 1.5 tap), Order kit Model No. 62-7040-00
Manifold Mount
For proper sealing, mating surface must be flat within .003, with a maximum surface roughness of 63 Ra μin surface finish.
HOW IT WORKS