1/2 -13
0.38
* Cylinder capacities are listed at 5,000 psi maximum operating pressure. The minimum operating pressure is 500 psi for D/A and 750 psi for S/A. The output force is adjustable by varying the hydraulic system divide the cylinder capacity shown in the table, by 5000 psi and multiply the result by your system pressure in psi to obtain the approximate cylinder force for your application. Actual force may vary slightly due to friction loss, seal and wiper drag, and/or return springs.
** Cylinder stroke may not exceed stroke of the clamping element. Limiting the stroke may be required to ensure proper operations of the clamping element.
*** At full cylinder capacity, fastener life will be limited, should be considered service item and replaced frequently to avoid plunger damage. Models 21-0206-00, 21-0209-00, 21-0210-00 and 21-0213-00 not recommended for use above 2500 psi.
**** Install included return spring for single acting operation. Return spring and anti-rotation pins included with cylinder.
NOTE: These features are only needed if anti-rotation pins are used. Anti-rotation and return springs are included with the cylinder. Anti-Rotation pins are intended for hand installation of bolt only. Do not torque bolt against anti-rotation pins.
1.25
0.81
Install included return spring for S/A operation.
Model No.
All dimensions are in inches.
*The 15° and 45° features of the cavity can be formed using an SAE 12, reduced spot face cutter except on models 21-0206-00 and 21-0206-01
*** Features for use with anti-rotate pins.
**** Lubricate o-rings with grease prior to installation.