Dimensions
All dimensions are in inches.
Operation: The Pressure Limiting Valve (PLV) is a Normally Open (N/O) pressure control device. The vale remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure the valve closes, blocking further flow and pressure rise to the downstream devices. The internal valve seal prevents fluid flow through the valve in either direction until the inlet pressure (power source to the valve) is reduced to near zero. The PLV is best suited for use in single-acting systems.
Once the PLV closes, it will remain closed until the inlet pressure is again reduced to zero.
Note: Maximum system flow rate is 1.5 gpm (350 cu. in. per minute) for all Vektorflo® special function valves.
Excess flow voids warranty
Cavity Dimensions for Cartridge
Note: For cavity tooling (multistep Reamer), order kit 62-7050-00.
If a Pressure Reducing Valve/Pressure Limiting Valve is no longer needed, use standard SAE#10 plug, 30-6011-99, to cap cavity for free fluid pass through.