Specifications
Port X Depth for Optional In-Port Valves*****
* Clamp capacities are listed at 1,000 psi maximum operating pressure with a standard length link clamp lever installed.
** Use of extended length levers will result in a reduction of clamp capacity. See graphs of lever output curves for clamping force of various lever lengths. Minimum operating pressure is 150 psi for double acting devices. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the clamp capacity shown above by 1,000 and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to mechanical inefficiencies and friction.)
*** To insure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings when clamping. If you are unable to measure flow rates, the devices should be positioned in no less than ½ second. These recommendations apply when using the standard lever. When using the optional long lever or your custom lever, please restrict the flow rates to position the arm in no less than 1 second.
**** Equal to ± 3° with standard lever
*****In-Port Valves require the use of manifold mount ports.
All dimensions are in inches.
Order levers separately
Double Acting
Levers are to be adjusted to within ± 3° of nominal clamp angle to prevent premature failure.