Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device.The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure the valve closes, blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point. The PRV is designed for use in both single and double acting systems.
NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all Vektorflo® special function valves.
Excess flow voids warranty.
Order a Filter Plate to protect valves from debris. (Model Number 70-8420-02).
Dimensions
Cartridge Dimensions
*Minimum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves. Excessive Flow
All dimensions are in inches.
Model No. 70-5437-70 and 70-5437-71
NOTE: For cavity tooling (multistep Reamer), order kit 62-7050-00.
If a PRV/PLV is no longer needed, use standard SAE#10 plug, 30-6011-99, to cap cavity for free fluid pass through.
The graph shows the repeat range based on set pressure.
The graphs show the pressure drop through a PRV and manifold mount block.
NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo® special function alves.