    Operating Parameter Guidelines

    • Max. Hydraulic Pressure: 5,000 psi
    • Max. Air Pressure: 200 ps
    • Max. Vacuum: 28 Hg
    • Max. Temperature: 400° F

    NOTE: Hoses alone should never be used to control the movement of a rotating union.

    Single Path Rotating Union NPT Ports
    Single Path Rotating Union NPT Port Dimensions
    Single Path Rotating Union Operating Limits
    Model No.
    32-1461-41
    Model No.Max RPM at 500 psi with Petroleum Based FluidsMax RPM at 1000 psi with Petroleum Based FluidsMax RPM at 2000 psi with Petroleum Based FluidsMax RPM at 3000 psi with Petroleum Based FluidsMax RPM at 4000 psi with Petroleum Based FluidsMax RPM at 5000 psi with Petroleum Based Fluids
    32-1461-4138019095655040