Language: EN

    Pressure Reducing Valve Control Block – Dual

    Accessory Valves

    • Control pressure independently on both the clamp and unclamp side of the fixture regardless of pump pressure setting.
    • Eliminate the wait for full system pressure to finish cycling workholding components.
    • For use in double or single acting systems.
    • DO3 Mounting, use on pump stack or as a remote mounted valve.
    • Recommended Filtration: 25 Micron (NOM) / 40 Micron (ABS) (minimum).

    * Maximum Inlet Pressure for Pressure Reducing Cartridges is 5,000 psi.​

    Pressure Reducing Valve Control Block - Dual Dimensions
    ils705406
    Model No.Inlet PressureSet Pressure RangeRepeatability
    70-8425-505000 psi750 - 4500 psi± 7%
    70-8425-53< 3000 psi / > 3000 psi150 - 900 psi / 300 - 900 psi± 10%
    Model No.AB
    70-8425-503.510.643
    70-8425-534.212.117