Language: EN

    Low-High Valve

    Metric Accessory Valves

    • Clamp with lower pressure to position parts then clamp with high pressure once sequence pressure has been met on the rest of the circuit.
    • Common inlet port feeds both sequence and reducing valves in parallel.
    • 5 (M8) manifold ports: 3x Inlet and 2x Outlet.
    • 4 (G1/4) ports: 2 x Inlet, 2x Outlet.
    • Use with single or double acting devices.
    • Block includes standard Sequence and PRV cartridges.
    • Can be sandwiched with a PRV/Sequence Combo block.
    • Enough space is provided on the block to accommodate a Gauge for setup or troubleshooting.
    • Recommended Filtration: 25 Micron (NOM) / 40 Micron (ABS) (minimum)

    ​* M8 Ports are counterbored for O-rings that are used in manifold mounting applications. Ø2.29 / 3.30 feed holes
    ** PRV set pressure range is: 10 – 60 bar with an inlet pressure of < 200 bar and  20 – 60 bar with an inlet pressure > 200 bar.

    Low-High Valve Dimensions

    For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 mµ Ra.

    Model No.Sequence Valve Model No.Sequence Valve Set Pressure RangePRV Model No.PRV Set Pressure Range
    47-0940-0447-0440-0052 - 350 bar47-0540-0052 - 310 bar
    47-0940-0547-0440-0052 - 350 bar47-0540-0410 - 62 bar **
    47-0940-0647-0440-0120 - 62 bar47-0540-0410 - 62 bar **
    Model No.AB
    47-0940-04117.9157.4
    47-0940-05117.9174.5
    47-0940-06133.0174.5

    You have questions? WE HAVE ANSWERS!

    Use the contact button below to be connected with one of our team of experts.