Specifications

Specifications
Model No. Clamp
Swing
Direction
Cylinder Capacity (lb.)** Vertical
Clamp
Stroke (in.)***
Total
Stroke
(Swing + Vertical)
Body
Dia.
Standard
Arm Length
Effective
Piston
Area
(sq. in.)
Oil
Capacity
(cu.in.)****
Port X For
Optional
In-Port
Valves*****
Retract Extend Retract
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.

14-6105-01-R
14-6105-01-L

14-6105-01-S

Right
Left
Straight
450 .22
.22
.57
0.57 0.99 1.06 0.098 N/A 0.056 SAE 2 X .48
14-6109-01-R
14-6109-01-L
14-6109-01-S
Right
Left
Straight
1100 .31
.31
.79
0.79 1.43 1.50 0.295 N/A 0.233

SAE 4 X .58

 
14-6113-01-R
14-6113-01-L
14-6113-01-S
Right
Left
Straight
2600 .50
.50
1.16
1.16 1.74 2.00 0.626 N/A 0.726 SAE 4 X .58

14-6118-02-R

14-6118-02-L

14-6118-02-S

Right
Left
Straight
5000 .62
.62
1.65
1.65 2.37 2.50 1.178 N/A 1.955

SAE 4 X .75

Double Acting (D/A) Cylinders, actuated hydraulically both directions.
14-6205-01-R
14-6205-01-L
14-6205-01-S
Right
Left
Straight
450 .22
.22
.57
0.57 0.99 1.06 0.098 0.142 0.056 SAE 2 X .48
14-6209-01-R
14-6209-01-L
14-6209-01-S
Right
Left
Straight
1100 .31
.31
.79
0.79 1.43 1.50 0.295 0.475 0.233 SAE 4 X .58
14-6213-01-R
14-6213-01-L
14-6213-01-S
Right
Left
Straight
2600 .50
.50
1.16
1.16 1.754 2.00 0.626 1.423 0.726

SAE 4 X .58

14-6218-02-R

14-6218-02-L

14-6218-02-S

Right
Left
Straight
5000 .62
.62
1.65
1.65 2.37 2.50 1.178 3.992 1.955

SAE 4 X .75

Warning! Never allow swing arm to contact workpiece or fixture during arm rotation.

** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure.

*** To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number X your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for work piece height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke.

**** To insure maximum service life and trouble-free operation, restrict fluid flow to the level indicated in the Clamp Time and Flow Rate Chart.

***** In-Port valves require the use of manifold mount ports.

 